Allegro MicroSystems, Inc. Site MapContact Us
中文English

High-Performance Power ICs and Hall-Effect Sensors

Current Sensors....

ACS760 Coolswap(TM) Solution

The current sensor families are innovative, monolithic, isolated Hall-effect based devices that provide a fully-integrated solution in industry-leading small-sized packages.

Key features:

  • Low insertion loss; power dissipation much less than shunt solution
  • Able to monitor both AC and DC currents
  • Smaller form factor than shunt and current transformer solutions
  • 5 V, single supply operation
  • Voltage isolation rating certified by TUV America
  • RoHS compliant

If you need to measure more than 200 A, please see the application note, Using Allegro Current Sensors in Current Divider Configurations for Extended Measurement Range.


Current Sensors
Type Part Number Measurement Range (A) Isolation Voltage (VRMS) Bandwidth (kHz) Temperature Ranges Packages Comments
Bidirectional ACS712 ±5 to 30 2100 80 E SOIC-8 Low noise, high speed current sensor with integrated shield
Unidirectional ACS713 20 to 30 2100 80 E SOIC-8 Unidirectional version of ACS712
Bidirectional ACS714 ±5 to 30 2100 80 L SOIC-8 Low noise, high speed current sensor with integrated shield
Unidirectional ACS715 20 to 30 2100 80 L SOIC-8 Unidirectional version of ACS714
Bidirectional ACS756 ±50 to 100 3000 120 S, K CA Most accurate, highest bandwidth current sensor for monitoring currents from 50 to 100 A
Bidirectional ACS754 ±50 to 200 3000 35 S, K, L CB Accurate current sensor for monitoring currents up to 50, 100, 150 and 200 A
Unidirectional ACS755 50 to 200 3000 35 S, K, L CB Unidirectional version of ACS754
Bidirectional ACS752 ±50 to 100 3000 50 S CA Improved accuracy over ACS750 current sensor
Bidirectional ACS750 ±50 to 100 3000 13 S, E, L CA  
Type Part Number Measurement Range (A) Voltage (V) Bandwidth (kHz) Temperature Ranges Packages Comments
Hot Swap Controller ACS760 55 12 to 20 50 E QSOP24 Hall Effect Hot-Swap Protection IC
  • 240VA – True Power Fault Monitor
  • Over-Current – Threshold set by user
  • Short Circuit - 2 µs response
  • FET Failure detection and alert

Copyright © 2008 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Worcester, MA 01606 USA Phone: 1.508.853.5000 Fax: 1.508.853.7895